About This File
Доработка инвертора при повторном выходе полевого транзистора Q7801 Countermeasure for Power Stop Symptom : LED BLINKING Cause : No power due to Q7801& Q7802 (standby-power stop) Applied Model : TH-19X10 SERIES Applied Chassis : KM02 Countermeasure : To protect Q7801 and Q7802 from surge voltage. a. Change R7801 from ERJ6GEYJ473V to ERJ6GEYJ103V To protect Q7801 and Q7802 part fail. b. Change C7801 from F2A1E101A134 to F2A1V221A470 (for life time) Market Actions: If market found Q7801 and Q7802 broken, apply the above countermeasure by replacing R7801 and C7801. Effective time : From FEBRUARY 21/02/2011. Что нового в этой версии Chassis KM02 (Посмотреть все изменения) POWER STOP KM02 L19X10 SERIES - от производителя