Перейти к содержанию

2 изображения

Информация о файле

TOSHIBA 49L621U  rev.A   

Shassi: SBB55T  VTV-L55730  REV;1   2016.03.31  

prots: MSD95M3D-5-004N  

panel K490WDR1

EMMC  100%\
Welcome to Medusa Pro Software version 2.0.5. 
 

Спойлер

Started.
Reader #0: Generic EMV Smartcard Reader 0

Please disconnect battery and USB cable.

Model Settings:
Interface : eMMC
Voltage   : 1.8V
Bus Mode  : 1 bit
Bus speed : Auto

Connecting...
Device       : Pretec eMMC M32508
Page size    : 512 B
Block size   : 512 B
Block count  : 7634944
Size         : 3728.00 MB
---------------------------------------------------------------
CID Info

CID                   : 7001004D3332353038521A4DB9928343
Manufacturer ID       : 0X70
Device/BGA            : BGA (Discrete embedded)
OEM/Application ID    : 0X00
Product name          : M32508
Product revision      : 5.2
Product serial number : (hex) 1A4DB992
Manufacturing date    : 08/2016
---------------------------------------------------------------
CSD Info

CSD                   : D04F01320F5903FFFFFFFFEF8A400061
CSD structure         : CSD version No. 1.2
SPEC version          : 4.1, 4.2, 4.3, 4.4, 4.41, 4.5,
                        4.51, 5.0, 5.01, 5.1
Data read access time1: 40 ms
TRAN speed            : 26 MHz
READ block length     : 512 Bytes
WP group enable       : YES
PERM_WRITE_PROTECT    : NO
TMP_WRITE_PROTECT     : NO
---------------------------------------------------------------
EXTCSD Info

Revision 1.8 (for MMC v5.1)
Erase block size      : 512 Kbytes
Boot1 size            : 4096 Kbytes
Boot2 size            : 4096 Kbytes
RPMB size             : 4096 Kbytes

Partition config      : (0x08) 00001000
Boot partition enable : Boot partition 1
(Bus width = 8Bit)
Boot ACK              : No boot acknowledge sent (default)

Boot bus conditions   : (0x02) 00000010
Boot bus width        : x8 (sdr/ddr) bus width in boot operation mode
Reset boot bus conditions   : Reset bus width to x1, single data rate and backward compatible timings after boot operation (default)
Boot mode             : Use single data rate + backward compatible timings in boot operation (default)

RST_n function        : (0x01) RST_n signal is permanently enabled

Partitioning support  : Device supports partitioning features
Enhanced attribute    : Device can have enhanced technological features in partitions and user data area.
Max enhanced data size: 3817472 Kbytes
Partitions attribute  : 0x1F
Part setting completed: 0x1
GP partition 1 size   : 0 b
GP partition 2 size   : 0 b
GP partition 3 size   : 0 b
GP partition 4 size   : 0 b
Enhanced area size    : (0xE9000000) 3728 MB
Enhanced area start   : (0x0) 0 b

Backup EXT_CSD saved to file C:/Program Files (x86)/Medusa Pro Software/EXT_CSD Backups/M32508_19_08_2020_15_03_10.bin.
Connect successful.
---------------------------------------------------------------
SW: 2.0.5; FW: 1.24.

 


Обратная связь

Вы сможете написать отзыв только после скачивания файла.
Чтобы скачать этот файл, вам нужно написать комментарий к файлу, указав что у вас сейчас в ремонте.
* Добавление фото Main, Panel и бирки на задней крышке TV обязательно!

Мы будем признательны за любую дополнительную полезную информацию по данной прошивке, которую вы сможете предоставить.
Ваши отзывы и отчеты помогут определить работоспособность загруженного дампa и подходит ли он для вашего телевизора, который вы указали в комментариях перед скачиванием этого файла.

×
×
  • Создать...

Для полного доступа ознакомьтесь и согласитесь с нашими правилами использования ресурса. Пожалуйста, уделите этому внимание и прочтите правила внимательно!

Правила Условия использования Политика конфиденциальности Мы разместили cookie-файлы на ваше устройство, чтобы помочь сделать этот сайт лучше. Вы можете изменить свои настройки cookie-файлов, или продолжить без изменения настроек.